Haier 600 Series QP Wall-Mounted Outdoor Unit – 1U35MAFFRA (1-Phase) (3.5kW / 3.7kW) Outdoor Unit Only

SKU: 51779-3.5KW-Out

$798.90

Haier 600 Series QP Wall-Mounted Outdoor Unit – 1U35MAFFRA (1-Phase) (3.5kW / 3.7kW)

Outdoor Unit Only

Best for:

  • Pairing with the Haier Quartz Plus (600 Series QP) 3.5kW indoor unit (AS35QCFHRA) for small to medium bedrooms, home offices, or compact open-plan living areas requiring high heating efficiency.

  • Outdoor installations in coastal or high-humidity regions, benefiting from Blue Fin anti-corrosion protection and outdoor Self-Clean functionality.

Key Features & Advantages:

  • High Heating Efficiency: Engineered for superior heating performance, meeting strict energy efficiency standards and rebate requirements.

  • Outdoor Self-Clean Technology: Uses freeze-and-defrost Cold Expansion technology to flush salt, dirt, and debris off the outdoor coil to prevent corrosion.

  • Hydrophilic Blue Fin Coating: Protective coating on the heat exchanger coil resists harsh ambient environmental elements and extends outdoor unit longevity.

  • DC Inverter Rotary Compressor: Delivers precise temperature regulation, low operational noise, and optimized energy consumption.

  • Eco-Friendly R32 Refrigerant: Utilizes lower-GWP R32 refrigerant (1.02 kg factory charge) for improved seasonal energy efficiency.

Performance Specifications (Paired with Indoor Unit AS35QCFHRA):

  • System Cooling Capacity (Rated): 3.5 kW (Range: 1.2 – 4.0 kW)

  • System Heating Capacity (Rated H1): 3.7 kW (Range: 1.3 – 4.2 kW) | H2 Low Temp: 3.7 kW

  • System Power Input (Rated): Cool 0.80 kW (0.25 – 1.30 kW) / Heat 0.83 kW (0.26 – 1.70 kW)

  • EER / AEER: 4.38 / 4.33

  • COP / ACOP: 4.46 / 4.42

  • ZERL Star Rating (Hot/Avg/Cold): Cool 5.0 / 4.5 / 4.5 | Heat 3.5 / 3.0 / 2.5

Outdoor Unit Specifications:

  • Compressor Type: Rotary

  • Outdoor Sound Pressure Level (SPL): 52 dBA

  • Outdoor Sound Power Level (SWL): 63 dBA

  • Outdoor Operating Temperature Range: Cooling -10°C to 46°C | Heating -15°C to 24°C

Technical & Piping Connections:

  • Power Supply: 1-Phase, 220-240V, 50Hz (Outdoor Cable Connection)

  • Electrical Parameters: RLA Cool 3.5 A / Heat 3.7 A | MCA: 7.5 A | Recommended Breaker: 16 A | Suggested Cable: 2.5 mm²

  • Liquid Pipe (Flare): Ø6.35 mm (1/4″)

  • Suction/Gas Pipe (Flare): Ø9.52 mm (3/8″)

  • Max Pipe Length / Max Level Difference: 15 m / 10 m (Min pipe length: 3 m)

  • Pre-Charge Pipe Length: 7 m (Additional charge: 20 g/m)

  • Refrigerant Type & Charge: R32 (1.02 kg)

Physical Dimensions & Weight:

  • Outdoor Unit Dimensions (H x W x D): 553 x 800 x 275 mm

  • Net Weight: 30.0 kg

Additional information

Or something else?

Help & Support

Need help with a product? Unsure of anything or just having issues? Jump to our Help & Support Page!

Contact our branches

Skip the hassle & contact our stores directly? For any specific queries, jump to our Contacts Page!

Christmas Holidays

Thanks eveyone for your patience. All online orders will be processed after our team returns after 5th January 2026!