Best for:
Pairing with the Haier Quartz Plus (600 Series QP) 5.0kW indoor unit (AS50QDFHRA) for medium-to-large living rooms, open-plan spaces, or master suites requiring efficient heating and cooling performance.
Outdoor installations in coastal or high-humidity regions, benefiting from Blue Fin anti-corrosion coil protection and outdoor Self-Clean functionality.
Key Features & Advantages:
High Heating Efficiency: Engineered for superior heating performance, meeting strict energy efficiency standards and rebate requirements.
Outdoor Self-Clean Technology: Uses freeze-and-defrost Cold Expansion technology to flush salt, dirt, and contaminants off the outdoor coil to prevent corrosion.
Hydrophilic Blue Fin Coating: Protective coating on the heat exchanger coil resists harsh ambient environmental elements and extends outdoor unit longevity.
DC Inverter Rotary Compressor: Delivers precise temperature regulation, low-vibration operation, and optimized energy consumption.
Eco-Friendly R32 Refrigerant: Utilizes lower-GWP R32 refrigerant (1.02 kg factory charge) for improved seasonal energy efficiency.
Performance Specifications (Paired with Indoor Unit AS50QDFHRA):
System Cooling Capacity (Rated): 5.0 kW (Range: 1.4 – 5.6 kW)
System Heating Capacity (Rated H1): 6.0 kW (Range: 1.5 – 6.5 kW) | H2 Low Temp: 5.8 kW
System Power Input (Rated): Cool 1.16 kW (0.36 – 1.90 kW) / Heat 1.48 kW (0.38 – 2.50 kW)
EER / AEER: 4.31 / 4.28
COP / ACOP: 4.05 / 4.03
ZERL Star Rating (Hot/Avg/Cold): Cool 4.5 / 4.0 / 4.0 | Heat 3.5 / 3.0 / 2.5
Outdoor Unit Specifications:
Compressor Type: Rotary
Outdoor Sound Pressure Level (SPL): 53 dBA
Outdoor Sound Power Level (SWL): 65 dBA
Outdoor Operating Temperature Range: Cooling -10°C to 46°C | Heating -15°C to 24°C
Technical & Piping Connections:
Power Supply: 1-Phase, 220-240V, 50Hz (Outdoor Cable Connection)
Electrical Parameters: RLA Cool 5.1 A / Heat 6.5 A | MCA: 11.0 A | Recommended Breaker: 16 A | Suggested Cable: 2.5 mm²
Liquid Pipe (Flare): Ø6.35 mm (1/4″)
Suction/Gas Pipe (Flare): Ø12.70 mm (1/2″)
Max Pipe Length / Max Level Difference: 25 m / 15 m (Min pipe length: 3 m)
Pre-Charge Pipe Length: 10 m (Additional charge: 20 g/m)
Refrigerant Type & Charge: R32 (1.02 kg)
Physical Dimensions & Weight:
Outdoor Unit Dimensions (H x W x D): 705 x 890 x 340 mm
Net Weight: 43.2 kg