Mitsubishi Heavy Industries SCM60ZS-W outdoor Unit
Power source (Outdoor): 1 Phase 240V 50Hz
Nominal Capacity (Range):
- Cooling T1: 6.0 kW (1.7~7.5kW)
- Heating H1: 6.8 kW (1.0~7.8kW)
Sound power level:
- Cooling T1: 62 dB(A)
- Heating H1: 64 dB(A)
Sound pressure level:
- Cooling T1: 50 dB(A)
- Heating H1: 52 dB(A)
Silent mode:
- Cooling T1: 43 dB(A)
- Heating H1: 44 dB(A)
External dimensions (HxWxD) : 640mmx850(+65)mmx290mm
Net weight: 48.5kg
Refrigerant (Type, amount, pre-charge length):
- Quantity: (R32) 1.8kg.
- Pre charged to pipe length: 40m.
Refrigerant piping:
- Liquid line: Ø6.35mm x 3
- Gas line: Ø9.52mm x 3
Connection method: Flare connection
Maximum pipe length to one indoor unit: 25m
Total pipe length to all indoor units: 40m
Max vertical height diff. between O.U. and I.U.: 15 ( O.U. above I.U.) / 15 ( O.U. below I.U. )
Outdoor air temperature (upper, lower limits):
- Cooling: -15 to 46 ℃
- Heating: -15 to 24 ℃
Indoor Unit Connection: 2 to 3 Units
Indoor Connection Capacity: 6.0 to 11.0 kW
MHI-NZ-Multi-SCM TECH PAGE